Logger Script

ÇöÀç À§Ä¡
home > ¹Ì»ý¹°¹èÁö Media > A-Z > A > AGS (Arginine Glucose Slant) Agar

AGS (Arginine Glucose Slant) Agar

»óÇ° ¿É¼Ç
¼ÒºñÀÚ°¡°Ý
106,000¿ø
ÆǸŰ¡°Ý
(ºÎ°¡¼¼ º°µµ)
106,000¿ø
»óÇ°¼±ÅÃ

      ÃÑ »óÇ° ±Ý¾× 0 ¿ø

      »óÇ° »ó¼¼¼³¸í Detail Product











      * Enterobacteria spp. ¿Í Vibrio spp. ¸¦ ºÐ¸®Çϱâ À§ÇÑ ¹èÁöÀÔ´Ï´Ù.

      * ¹èÁö Á¦Á¶ ½Ã ½ÃÇè°ü¿¡ ¹èÁö¸¦ ºÐÁÖ ÈÄ ±â¿ïÀÎ »óÅ¿¡¼­ ±»Çô »ç¿ëÇÏ´Â »ç¸é¹èÁöÀÔ´Ï´Ù. °ø±â¿ÍÀÇ Á¢ÃËÀÌ ÀûÀº °íÃþºÎ¿Í Á¢ÃËÀÌ ¸¹Àº »ç¸éºÎÀÇ °á°ú¸¦ ³ª´²¼­ È®ÀÎÇϸç Ȳȭ¼ö¼Ò ¹ß»ý¿©ºÎµµ °íÃþºÎ¿¡¼­ È®ÀÎÀÌ °¡´ÉÇÕ´Ï´Ù.

       

       

       

      AGS (Arginine Glucose Slant) Agar [MB-A0812]

                                                                                                                                                         



       

      Medium used for the differentiation of Enterobacteria spp. and Vibrio spp..

       

       

       

      PACKAGE

       

      Description

      Quantity

      Cat. No

      AGS (Arginine Glucose Slant) Agar

      500g

      MB-A0812

      AGS (Arginine Glucose Slant) Agar

      *500ml x 10

      MB-A0812M

      500ml x 10 Á¦Ç°ÀÇ °æ¿ì, 500ml ¹èÁö¸¦ Á¦Á¶ÇÒ ¼ö Àִ ÆÄ¿ì´õ ¾ç¸¸Å­ ¼ÒºÐµÇ¾îÀִ Á¦Ç°ÀÔ´Ï´Ù.

       

       

       

       

      PROCEDURE

       

      Suspend 58.32 G of powder in 1 L of distilled or deionized water. Heat to boiling until completely dissolved. Sterilize by autoclave at 121¡ÆC for 10 - 12 minutes. Cool to 45-50¡ÆC in water bath. Dispense in tubes. Arrange tubes in a slanted position. If necessary, dispense the medium before autoclave.

       

       

      STORE

       

      The powder is very hygroscopic. Store the powder at room temperature, in a dry environment, in its original container tightly closed and use it before the expiry date on the label or until signs of deterioration or contamination are evident. Store prepared medium at 2 - 8¡ÆC.







       

      * º» Á¦Ç°Àº Á¦Á¶ ¶Ç´Â À¯Åë »ó¿¡¼­ º¯ÁúµÉ °¡´É¼ºÀÌ ÀÖÀ¸´Ï »ç¿ë Àü È®ÀÎÇÏ¿© Áֽñ⠹ٶø´Ï´Ù.

      * This product may have contamination risk during the manufacturing or delivering, so please check before use it.

      ¸®ºäÀÛ¼º Review Board Àüüº¸±â

      review ÀÛ¼º Æû
      review board
      ÀÌ ¸§ :
      ÆòÁ¡ :      
      ³»¿ë
      Èı⾲±â
      review ¸®½ºÆ®
      À̸§
      ³»¿ë
      ÆòÁ¡
      ³¯Â¥

      »óÇ°¹®ÀÇ Q&A Board Àüüº¸±â »óÇ°¹®ÀÇ

      QnA ¸®½ºÆ®
      µî·ÏµÈ ¹®ÀÇ°¡ ¾ø½À´Ï´Ù.

      »ó´ÜÀ¸·Î À̵¿

      Item size chart »çÀÌÁî ±âÁØÇ¥

      * »óÇ°»çÀÌÁî Ä¡¼ö´Â Àç´Â ¹æ¹ý°ú À§Ä¡¿¡ µû¶ó 1~3cm ¿ÀÂ÷°¡ ÀÖÀ» ¼ö ÀÖ½À´Ï´Ù.

      ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â